Metal wall panels · Capital Region
ACM and aluminum plate panel subcontracting
Aluminum composite panels, formed plate panels, storefront sign bands, column covers, trims and soffits coordinated cleanly with surrounding facade systems.
Call or text (518) 888-7938
Book spring work now. Winter assessments and estimates available.
Updated November 2026

Short answer
We furnish and install aluminum composite (ACM) and formed aluminum plate panels, storefront sign bands, column covers, fascia trims and soffits for general contractors in the Capital Region. Pairing metal panels with EIFS and fluid-applied air barriers under one exterior sub keeps sub-framing depths, flashing transitions and sealant joints aligned across the facade. Send elevations and Division 07 specs for pricing.
Key facts
- Service area
- Albany, Schenectady, Troy, Saratoga Springs, Glens Falls and jobs within about two hours of Albany.
- Season
- EIFS and stucco finishes need about 40 °F and rising, with no freezing for 24 hours. In the Capital Region that means spring through late fall.
- Who does the work
- Our own crews, from The Dom Construction Group LLC.
- Insurance
- General liability, umbrella and workers' compensation insurance; certificates on request.
- Estimates
- Free. Start with 3–5 photos by text, or use the form.
- Reply
- We reply within one business day, Monday to Friday.
ACM and plate panel installation paired with wall systems
Retail storefronts, medical office buildings, auto dealerships, schools and mixed-use facades across the Capital Region frequently combine smooth metallic entries, canopies and sign bands with textured EIFS or masonry wall fields. Subcontracting aluminum composite material (ACM) and plate panels alongside commercial drainage EIFS and fluid-applied air and water barriers eliminates one of the trickiest coordination headaches on a commercial facade: getting two competing wall trades to agree on wall depth, head flashings and shared joint lines.
518 GC Exteriors furnishes and installs fabricated ACM panels, solid formed aluminum plate panels, column covers, fascia bands, parapet copings and vented or solid metal soffits. Our own crews install the sub-framing, set the panels from our own pipe and frame scaffold or lifts, and complete the perimeter transitions so the finished elevation reads with straight sightlines and crisp reveals.
Sub-framing, continuous insulation and joint layout
Metal panel facades are only as flat and watertight as the framing plane behind them. Depending on your Division 07 specification and energy-code assembly, we work with two primary panel attachment approaches:
- Drained and back-ventilated rainscreen assemblies: Extruded aluminum perimeter tracks, clip systems and open or baffled spline joints that equalize wind pressure behind the panel face and vent moisture out above flashings.
- Rout-and-return wet-sealed assemblies: Fabricated composite or plate cassettes fastened through concealed perimeter flanges, finished with closed-cell backer rod and color-matched low-modulus silicone waterproofing sealant at panel joints.
Behind the panels, exterior continuous insulation—mineral wool or rigid foam board—has to align cleanly with sub-girts, thermally broken clips or hat channels without crushing the insulation or bridging water past the air and water barrier. During shop-drawing review we verify total wall buildup depth so panel faces sit at the exact design projection relative to storefront mullions and adjacent EIFS bands.
Field dimensions and clean tie-ins to EIFS or masonry
Unlike field-cut siding, rout-and-return ACM and brake-formed plate panels cannot simply be trimmed on a sawhorse without ruining their return flanges and factory fluoropolymer finish. Accurate panel fit requires disciplined field verification once structural steel, canopy framing, light-gauge stud walls and window frames are locked in place.
Our foreman shoots field dimensions across openings, column lines, canopy corners and soffit drops before releasing final panel fabrication sizes—or coordinates hold-to dimensions with your framing trade when schedule milestones demand early release. Where an aluminum fascia or sign band meets EIFS or stucco, we detail positive-slope drip edges, back-wrapped EIFS terminations with sealant receivers, and continuous membrane continuity behind both claddings so runoff from smooth metal surfaces does not streak or saturate the textured wall below.
Submittals, finish samples and fabrication timing
Lead times on coil-coated ACM sheets, custom Kynar/PVDF colors, anodized finishes and shop-fabricated corner or curved column panels often govern the exterior closeout path. When you invite us through our bid desk, we flag standard-chart versus custom-run coil lead times right in our proposal so your project manager knows when color approvals and field measurements must occur. Once under contract, we submit engineered or shop-drawn panel layouts, attachment details, sealant color charts and physical metal color chips early so procurement stays ahead of your facade schedule.

AI-generated illustration
Aluminum composite and plate panel questions
What is the difference between ACM panels and formed aluminum plate panels?
Aluminum composite material (ACM) bonds two thin pre-finished aluminum skins to a polyethylene or fire-retardant mineral core, delivering very flat panels at lighter weight for storefronts, canopies and fascia bands. Solid aluminum plate panels are brake-formed from thicker monolithic aluminum sheet—often eighth-inch plate—chosen where specs call for non-combustible solid metal, heavy impact resistance or custom welded corners.
When should metal panel field dimensions be taken on a new building?
Fabricated ACM and plate cassettes have pre-routed return legs that cannot be field-trimmed like lap siding. Final verification measurements happen once structural steel, canopy outriggers, exterior stud framing and storefront frames are installed. When tight project schedules require early panel release, we establish agreed hold-to framing dimensions on shop drawings with the general contractor and framing sub.
How do continuous exterior insulation and sub-girts work behind metal panels?
Energy-code commercial walls typically place mineral wool or rigid insulation outside the sheathing and air barrier. To support aluminum panel tracks without creating severe thermal bridges or crushing the insulation, thermally isolated clips and metal Z-girts or hat channels attach back into structural studs or masonry, holding panel rails at a true, shimmed plane outside the insulation layer.
How do you detail the joint where an ACM sign band meets EIFS?
Dissimilar materials move at different rates and shed water differently. Where an aluminum fascia or sign band meets commercial EIFS, the air and water barrier runs continuously behind both claddings, the EIFS edge is fully back-wrapped with reinforcing mesh, metal drip or receiver flashings shed runoff clear of the textured wall, and a sized backer-rod-and-sealant joint absorbs thermal expansion.
Do you also install metal soffits, column covers and parapet copings?
Yes. Storefront entries and canopies usually wrap ACM or aluminum panels from the vertical fascia underneath into solid or vented soffits and down round or square column covers. Keeping canopy fascias, soffits, column wraps and adjacent parapet copings with the same facade crew prevents color-lot mismatches, misaligned panel joints and unsealed corners where vertical walls meet overhead ceilings.
Send elevations for aluminum panel pricing
Include architectural elevations, wall sections and Division 07 metal panel specifications.
Companion facade scopes
- Commercial EIFS
Pair smooth metal entry canopies and bands with insulated EIFS wall fields.
- Prefabricated EIFS panels
Unitized EIFS bands when weight, profile or schedule favors panelized foam.
- Air & water barriers
Continuous weather barriers behind rainscreen sub-framing and insulation.
- Bid with us
How we handle coil lead times, submittals and scope letters.
Adding ACM sign bands or soffits to your facade package?
Book spring work now. Winter assessments and estimates available.